24 Immediately Placed and Loaded Implants
This case demonstrates the surgical placement and restoration of 24 immediately placed and loaded implants.
View ArticleRestoration of a Maxillary Right Central Incisor with an e.max® CAD/CAM Crown
This case demonstrates the uncovering and restoration of a maxillary right central incisor 4.0 x 8.0mm Bicon implant with an abutment with a titanium base and extra-orally cemented zirconia sleeve...
View ArticleRestoration of a Maxillary Left Central Incisor with an e.max® CAD/CAM Crown
This case demonstrates the two-stage placement of a 4.5 x 8.0mm SHORT® Implant, its uncovering, implant-level transfer impression, and restoration for a maxillary left central incisor with an abutment...
View ArticleTwo Stage Placement, Uncovering, and Restoration of a Mandibular Posterior...
This case demonstrates the two-stage placement of a 4.5 x 6.0mm SHORT® Implant, its uncovering, implant-level transfer impression, and restoration for a mandibular right first molar.
View ArticleTwo Stage Placement, Uncovering and Restoration of a Maxillary Left Central...
This case demonstrates the extraction, two-stage placement of a 4.0 x 8.0mm implant with 2.5mm well, its uncovering, implant-level transfer impression, and restoration of a maxillary left central...
View ArticleMaxillary Anterior Placement of a 4.0 x 8.0mm Bicon Implant with SynthoGraft™
This case demonstrates the two-stage placement of a maxillary anterior 4.0 x 8.0mm implant with SynthoGraft™ and Leukocyte and Platelet Rich Fibrin (LPRF).
View ArticleExtraction and Immediate Placement of a 3.0 x 8.0mm NARROW™ Implant for a...
This case demonstrates the insertion, restoration, and interdental papillae maturation of a 3.0 x 8.0mm NARROW™ Implant for a mandibular right central incisor over the course of a two-year period. This...
View ArticleFour Immediately Placed and Loaded Maxillary Incisors
This case demonstrates the use of a TRINIA™ transitional prosthesis and four Bicon Universal Abutments to stabilize four immediately placed 4.0 x 6.0mm SHORT® Implants after the extraction of four...
View ArticlePlacement and Immediate Load of Two Maxillary Central Incisor Implants
This case demonstrates the immediate placement and loading of two maxillary central incisor implants using a TRINIA™ and Ceramage transitional prosthesis and two Bicon Universal Abutments to stabilize...
View ArticlePlacement and Restoration of a 3.0 x 6.0mm SHORT® Implant in a Seemingly...
This case demonstrates three years of remarkable healing and clinical capabilities of a Bicon implant which was restored with an Integrated Abutment Crown™ (IAC) in a seventy-two-year-old male patient....
View ArticleFabrication and Insertion of a Four-Implant Mandibular Full Arch TRINIA™...
This case demonstrates the fabrication of a four-implant mandibular full arch TRINIA™ telescopic prosthesis, beginning with the making of an implant-level transfer impression and bite registration,...
View ArticleRestoration of a Maxillary Left First Molar with an Abutment-Level Transfer...
This case demonstrates the process of fabricating an abutment-level transfer impression and a transitional crown with a 5L Universal Abutment after uncovering the implant in the area of the maxillary...
View ArticleExtraction of a Maxillary Left First Premolar and its Replacement with a...
This case demonstrates the extraction of a maxillary left first premolar and its replacement with a SHORT® 4.5 x 6.0mm implant using SynthoGraft™, Leukocyte and Platelet Rich Fibrin (LPRF), and...
View ArticleImmediate Placement and Restoration of a Maxillary First Molar with an...
This case demonstrates the extraction of a maxillary first molar and the immediate placement of a 6.0 x 6.0mm implant. Additionally, three different impression techniques are presented: implant-level...
View ArticleGuided Bone Regeneration Technique and Implant Placement in an atrophic...
This treatment offers an alternative to ridge splitting procedures, demonstrating the molar implant placement and simultaneous guided bone regeneration of a 56-year-old woman’s atrophic left mandible....
View ArticleImmediate Loading of Three Maxillary Implants with a Winged TRINIA®...
This treatment demonstrates the technique of immediately loading two 4.0 x 6.0mm implants and one 5.0 x 5.0mm implant by using a winged TRINIA® transitional prosthesis and one existing 4.5 x 8.0mm...
View ArticleLaboratory and Clinical Aspects of Fabricating and Inserting Four Universal...
This treatment depicts the detailed aspects and nuances of the above-described prostheses in only three clinical restorative visits, which included: During the first visit, the surgical uncovering of...
View ArticleAnterior Placement of Two 3.0 x 6.0mm SHORT® Implants with Mandibular Central...
This treatment demonstrates the placement of two 3.0 x 6.0mm SHORT® Implants with 2.0mm wells and the insertion of two mandibular central incisor Integrated Abutment Crowns™ (IACs).
View ArticleImmediate Load of Three Maxillary Incisor 4.5 x 8.0mm Implants
This treatment demonstrates the extraction of teeth #8, 9, and 10, and the subsequent placement and immediate loading of three 4.5 x 8.0mm implants with 2.5mm wells, the preparation of the osteotomy...
View ArticleReplacement of a Failed Screw-Retained Prosthesis with a Telescopic...
This treatment for an 83-year-old woman, who presented with a failed maxillary prosthesis supported by five screw-retained IMZ implants, demonstrates the clinical capabilities of a telescopic TRINIA®...
View ArticleImplant Placement and Restoration of a Six-Unit Cemented TRINIA® Prosthesis...
This treatment demonstrates the extraction of a maxillary lateral incisor and the immediate placement of a 4.0 x 6.0-mm implant with a 2.5-mm well for a 91-year-old man. An implant-level transfer...
View ArticleOne-Stage Surgical Placement of Two Maxillary and One Mandibular Congenitally...
This treatment demonstrates the Bicon one-stage surgical technique with transmucosal Temporary Abutments for three congenitally missing lateral incisors in a 21-year-old man and their subsequent...
View ArticlePlacement of Three 4.5 x 6.0mm Bicon SHORT® Implants, Grafting with...
This treatment demonstrates the placement of three maxillary 4.5 x 6.0mm Bicon SHORT® Implants using SynthoGraft™ and two collagen membranes to graft a significant bony defect. The uncovering of the...
View ArticleImmediate Load of Two 4.0 x 8.0mm and Two 4.5 x 8.0mm Bicon SHORT® Implants...
This treatment demonstrates the removal of two canine root tips, and the immediate placement and loading of two 4.0 x 8.0mm and two 4.5 x 8.0mm Bicon SHORT® implants with four Universal Abutments in...
View ArticleRestoration of Three Immediately Placed and Loaded 4.5 x 8.0mm Bicon SHORT®...
This treatment demonstrates the one-stage placement of one 4.5 x 8.0mm Bicon SHORT® Implant with a collagen membrane and the immediate placement and loading of three 4.5 x 8.0mm Bicon SHORT® Implants....
View ArticleRidge Split and Implant Placement for a Congenitally Missing Maxillary Right...
This treatment demonstrates a Ridge Split procedure and placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a congenitally missing maxillary right lateral incisor in an adolescent patient, its...
View ArticleImmediate Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Mandibular...
This treatment demonstrates the extraction of a mandibular primary tooth and the immediate placement of a 5.0 x 6.0mm Bicon SHORT® Implant using the one-stage technique with a tranmucosal temporary...
View ArticleGuided Surgery and Two-Stage Technique for the Restoration of a 5.0 x 5.0mm...
This treatment demonstrates the restoration of a 5.0 x 5.0mm Bicon SHORT® Implant for a mandibular right second molar with an Integrated Abutment Crown™ (IAC) using guided surgery and a two-stage...
View ArticleRestoration of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary Right...
This treatment demonstrates the restoration of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor using the two-stage technique with bone grafting of a labial fenestration using...
View ArticleRestoration of a Maxillary Left Second Premolar with a 4.5 x 5.0mm Bicon...
This treatment demonstrates the restoration of a maxillary left second premolar with a 4.5 x 5.0mm Bicon SHORT® Implant using the two-stage technique with SynthoGraft™ and a Collagen Membrane, as well...
View ArticleGuided Surgery with Two-Stage Technique for the Restoration of a 5.0 x 8.0mm...
Using the Bicon Guided Surgery Technique, a 5.0 x 8.0mm Bicon SHORT® Implant was placed with a two-stage surgery for a mandibular right first molar and restored with an Integrated Abutment Crown™...
View ArticleTwo-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an Internal...
This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant with an internal sinus lift procedure using guided surgery for a maxillary right first molar and its...
View ArticleOne-Stage Placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a Maxillary...
This treatment demonstrates the placement of a 5.0 x 8.0mm Bicon SHORT® Implant for a maxillary right first molar using the one-stage surgical technique, the restoration with a full arch implant-level...
View ArticleTwo-Stage Placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a Maxillary...
This treatment demonstrates the two-stage placement of a 4.5 x 8.0mm Bicon SHORT® Implant for a maxillary right central incisor five months after grafting a large buccal defect and using SynthoGraft™,...
View ArticleTwo-Stage Placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a Maxillary...
This treatment demonstrates the two-stage placement of a 5.0 x 6.0mm Bicon SHORT® Implant for a maxillary left second premolar, the making of its full arch implant-level transfer impression, and its...
View ArticleRemoval of a Traumatically Fractured Maxillary Left Central Incisor and the...
This treatment demonstrates the removal of a maxillary left central incisor six days after its being traumatically fractured, and the immediate loading of a 4.0 x 6.0mm Bicon SHORT® Implant with a 5...
View Article17-Year Follow Up for Two Immediately Loaded Maxillary Central Incisors
This case demonstrates the extraction of two failed endodontically-treated maxillary central incisors, the immediate surgical placement and stabilization of two 5.0 x 8.0mm Bicon SHORT® Implants, and...
View ArticlePlacement of Two 4.5 x 8.0mm Bicon SHORT® Implants and their Restoration with...
This treatment demonstrates the extraction of a deciduous maxillary right lateral incisor and its replacement with a 4.5 x 8.0mm Bicon SHORT® Implant adjacent to a congenitally missing canine, as well...
View ArticleImmediate Loading Using Guided Surgery for Two Maxillary Incisor SHORT®...
This case demonstrates the extraction of three maxillary incisor teeth and, using guided surgery, the placement of two 4.5 x 8.0mm SHORT® Implants for immediate loading with a prefabricated five-unit...
View ArticleImmediate Loading of Two Bicon SHORT® Implants and Two Temporary Implants...
This case demonstrates the extraction of three maxillary anterior teeth, the placement and immediate loading of two 4.5 x 8.0 mm Bicon SHORT® Implants and two 8.0mm Fixed-Detachable Universal Temporary...
View ArticleTwo Full-Arch TRINIA® Telescopic Restorations Featuring Seven Implant...
This case demonstrates the extraction of six teeth and the placement of four maxillary implants (two using sinus lift abutments and others using bone grafting procedures with SynthoGraft™ and Bicon...
View ArticlePlacement and Immediate Loading with a Mandibular Full-Arch TRINIA®...
This case demonstrates the placement of two 4.0 x 6.0mm and two 4.0 x 8.0mm Standard Profile Fixed-Detachable Universal Abutment Transitional Implants using guided surgery and their immediate loading...
View ArticleOne-Stage Immediate Placement of a Bicon SHORT® Implant Using a Scannable...
This case demonstrates the extraction of a mandibular lower left central incisor, the one-stage immediate placement of a 3.5 x 8.0mm SHORT® Implant with a 4-Series Scannable Temporary Abutment with a...
View ArticleSeven-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant Using...
This case radiographically demonstrates the extraction, implant placement of a 6.0 x 5.0mm Bicon SHORT® Implant with a Sinus Lift Abutment, and its restoration with a 20mm long Integrated Abutment...
View ArticleTwelve-Year Radiographic Follow Up of a 6.0 x 5.0mm Bicon SHORT® Implant with...
This case radiographically demonstrates the extraction, implant placement of a 6.0 x 5.0mm Bicon SHORT® Implant with an internal sinus lift using SynthoGraft™, and restoration with an Integrated...
View ArticleReplacement of a Failed Full-Arch Maxillary PFM Prosthesis with a TRINIA®...
This case demonstrates both the surgical and prosthetic treatments, which provided a seventy-five-year-old professional male patient (who travels frequently) with the comfort of having a fixed...
View ArticleBicon Scannable Temporary Abutments Provide for Crown Fabrication While...
This case demonstrates the time-saving benefits for patients, technicians, and clinicians alike when Bicon Scannable Temporary Abutments are used with the one-stage implant placement protocol. The...
View ArticleDigital Impression of Two Scannable Temporary Abutments and the Subsequent...
This case demonstrates how using Bicon Scannable Temporary Abutments with the one-stage implant protocol can save time for patients, technicians, and clinicians. It reduces chairtime, minimizes failed...
View ArticleMaxillary First Molar Sectioning, Extraction, and One-Stage Immediate Implant...
This case demonstrates the buccal sectioning of a 78-year-old male patient’s maxillary left first molar and the subsequent extraction of its palatal root and gold crown. Before removing the buccal...
View ArticleMandibular Premolar Extraction, and One-Stage Immediate Implant Placement...
This case demonstrates the extraction of a 60-year-old male patient’s mandibular right first premolar, the immediate placement of a 5.0 x 6.0mm SHORT® Implant, the uncovering of the integrated right...
View Article